I. OVERVIEW
MGG High Pressure Electromagnetic Flowmeter is composed of high-pressure electromagnetic flow sensor which is manufactured with special technics and expertise and MGG 24C converter , It is specially used in.
II. CHARACTERISTICS
- Measurement is independent of fluid density, viscosity, humidity, temperature, pressure and conductivity.
- There are no obstacle part in the measuring tube, no pressure damage to the tube of which the straight part is of low requirement.
- The sensor with grounded electrode guarantees the grounding well.
- The sensor with advanced processing technology is of nice resistance to the negative pressure.
- The liquid crystal display in the converter of the Magne W3000 PLUS makes the reading easy under the sun or in the dark room.
- The converter of the Magne W3000 PLUS can at the same time display the percentage of volume flow, the real flow and accumulative flow.
- Installed on the tube forming with the standard type on angle equal to or small than 90°, the revolving display screen improves the visibility of the integrated flow meter.
- In bad environment parameter can be without uncovering the cover of the converter set up through the infrared ray touch nub.
- The converter has alarm output function of self-diagnosis, empty load test, high and low limit of the flow, two-stage flow value, etc.
- High-pressure type electromagnetic flow sensor using F46 lining manufactured with special technics and expertise is specially applied in industries of oil, chemistry etc.
III. TECHNICHAL PARAMETERS
- Nominal Bore: DN25~DN100
- Accuracy: ±0.5%, ±0.3% or ±0.2%
- Lining material: F46
- Electrode material: 316L Stainless steel
- Conductive ratio of the medium: ≥3μs/cm
- Nominal Pressure: 6.3, 10, 16, 25, 32MPa
- Temperature of Medium: 0~+80℃(Converter) 0~+180℃(Sensor)
- Ambient Temperature: -25℃~+60℃
- Power supply: 220V 50Hz or 24VDC
- Connection Mode: Flange mode
|
 |
|