I. OVERVIEW
MGG Smart Electromagnetic Flowmeter is of perfect performance and reliability. Based on the successfully proved Magne W3000 flow technology of Yamatake Corporation, the flowmeter is widely used in industries of petroleum, chemical engineering, metallurgy, food, electric power, papermaking, water treatment, etc.
II. CHARACTERISTICS
- Measurement is independent of fluid density, viscosity, humidity, temperature, pressure and conductivity.
- There are no obstacle part in the measuring tube, no pressure damage to the tube of which the straight part is of low requirement.
- The sensor with grounded electrode guarantees the grounding well.
- The sensor with advanced processing technology is of nice resistance to the negative pressure.
- The liquid crystal display in the converter of the Magne W3000 PLUS makes the reading easy under the sun or in the dark room.
- The converter of the Magne W3000 PLUS can at the same time display the percentage of volume flow, the real flow and accumulative flow.
- Installed on the tube forming with the standard type on angle equal to or small than 90°, the revolving display screen inpore the visibility of the integrated flow meter.
- In bad environment parameter can be without uncovering the cover of the converter set up through the infrared ray touch nub.
- The converter has alarm output function of self-diagnosis, empty load test, high and low limit of the flow, two-stage flow value, etc.
- Soak-proof and diving electromagnetic flow-meter offers excellent survey of flow and its process.
- The sensor of high-voltage-electromagnetic flowmeter is made with patent technology and specially applied in industries of petroleum , chemical engineering ,etc.
III. TECHNICHAL PARAMETERS
- Nominal Bore: DN15~DN3000
- Accuracy: ±0.5%, ±0.3% or ±0.2%
- Medium Temperature : Remote type -10℃~+80℃(PTFE/F46 Lining: -10℃~+80℃) Integral type -10℃~+80℃
- Ambient Temperature: -25℃~+60℃
- Ambient Humidity: 5~100%RH (Relative Humidity)
- Conductive Ratio of the Medium: ≥3μs/cm
- Measuring Range: 1500:1 Flow velocity setting < 15m/s
- Connection: Integral model / Remote model
- Housing Protection: flow sensor IP65, IP68 Optional
- Converter: IP67
- Ex-proof mark: Sensor of Ex-proof type ExmIIT4
- Convert of Ex-proof type: Ⅰ/Ⅱ/Ⅲ, Group A\B\C\D\F\G of the Second Area, or area of no danger
|
 |
|